Stryker 1588 AIM Camera Console System 1588AIM 1588-010-000
Stryker 1588 AIM Camera Console System 1588AIM 1588-010-000
Stryker 1588 AIM Camera Console System | Part# 1588-010-000
- • Stryker 1588 AIM / 1588010000 AIM camera console system
- • 1920x1080p HD with 3-CMOS sensors
- • Dynamic Range Enhancement brightens dark cavities
- • Near-infrared imaging with Stryker L10 LED light source
- • Refurbished units, repair, exchange
Need service or repair? No matter the age, brand, or manufacturer Ampronix can repair it! Free, no charge for initial evaluations!
Couldn't load pickup availability
Details
Details
Stryker 1588 AIM (1588010000) AIM camera console system. Ampronix offers refurbished Stryker 1588 AIM units, service and repair, and replacement and exchange. Both the 1588-010-000 and 1588010000 model numbers are supported.
Manufacturer: Stryker, Model: 1588 AIM, Part number: 1588-010-000 (also written 1588010000)
The Stryker 1588 AIM Camera Console System (part number 1588-010-000 / 1588010000) is Stryker's next-generation Advanced Imaging Modalities (AIM) endoscopic camera platform, engineered for premium HD visualization across surgical specialties. The Stryker 1588 AIM (1588010000) delivers 1920x1080p HD resolution from HD progressive scan 3-CMOS sensors, nine surgical specialty settings, Dynamic Range Enhancement (DRE) that illuminates dark and posterior surgical cavities by up to 150%, and Endoscopic Near-Infrared Visualization (ENV) for infrared-compatible imaging when paired with the Stryker L10 LED Light Source with AIM Technology.
Where it is used
The Stryker 1588 AIM Camera Console System (1588-010-000) is deployed in hospital ORs and ambulatory surgery centers running laparoscopic general surgery, laparoscopic cholecystectomy, knee and shoulder arthroscopy, ureteroscopy, cystoscopy, hysteroscopy, laparoscopic gynecology, functional endoscopic sinus surgery (FESS), upper and lower GI endoscopy, and colonoscopy. The Stryker 1588 AIM platform is specifically designed for cross-specialty standardization, a single 1588 AIM console handles all procedure types, making it the system of choice for facilities standardizing their OR imaging infrastructure. The DRE and ENV advanced imaging modes also make the Stryker 1588 AIM a preferred platform for complex minimally invasive procedures where posterior compartment visualization is critical.
System components and compatible part numbers
- Camera Control Unit (CCU): 1588-010-000 (also 1588010000, 1588-010-000), the console covered by this listing
- Camera heads: 1588-210-105 (C-Mount), 1588-310-130 (pendulum with integrated coupler), 1588-610-122 (integrated coupler), 1588-710-105 (inline C-Mount)
- Coupler: 1588-020-122 (18mm C-Mount)
- Compatible light source for ENV mode: Stryker L10 LED with AIM Technology (0220-220-300)
- Compatible standard light source: 1588 AIM Light Source (0220220100)
- Compatible capture system: Stryker SDC3 HD / SDC3HD Information Management System (0240060100)
Model: 1588-010-000 / 1588010000
Related: Medical Cameras, Stryker products, Refurbished products.
Frequently asked questions about the Stryker 1588 AIM
Is the Stryker 1588 AIM AIM camera console system available for sales, service and repair, replacement and exchange?
Yes. Ampronix offers refurbished units of the Stryker 1588 AIM, plus service and repair, replacement and exchange, subject to availability. Both the 1588-010-000 and 1588010000 versions are covered. Call Ampronix for current availability and a quote.
Does Ampronix repair the Stryker 1588 AIM?
Yes. Ampronix provides service and repair for the 1588-010-000 (1588010000) with free evaluation and fast turnaround. Call Ampronix for a repair quote.
Can I exchange or replace my 1588-010-000?
Yes. Ampronix offers replacement and exchange options for the 1588-010-000. Call Ampronix to confirm availability and pricing.
Where can I buy a Stryker 1588 AIM AIM camera console system?
Ampronix sells the Stryker 1588 AIM (1588010000). Call Ampronix for current availability, pricing and lead time.
Is the 1588-010-000 the same as the 1588010000?
Yes. 1588-010-000 and 1588010000 are two ways of writing the same model number, and Ampronix supplies and services both.
Should I repair or replace my 1588-010-000?
Ampronix can quote repair, exchange or replacement for the 1588-010-000 so you can compare options. Call Ampronix for a free evaluation.
What should I have ready when I request a quote for the 1588-010-000?
Have the model number (1588-010-000 or 1588010000), the serial number from the unit label if you have one, and whether you need a unit, a repair or an exchange.
What are the key features of the Stryker 1588 AIM?
Key points for the Stryker 1588 AIM: 1920x1080p HD with 3-CMOS sensors; Dynamic Range Enhancement brightens dark cavities; Near-infrared imaging with Stryker L10 LED light source. Call Ampronix to confirm details for your application.
What is Dynamic Range Enhancement (DRE) on the Stryker 1588 AIM?
DRE is a built-in advanced imaging feature of the Stryker 1588 AIM (1588-010-000) that selectively brightens dark and posterior compartments of the surgical image by up to 150%, helping surgeons identify anatomy in difficult-to-illuminate areas. DRE is activated with a single button press on the 1588 AIM camera head.
What is the difference between the Stryker 1588 AIM and the Stryker 1288 HD?
The Stryker 1588 AIM (1588-010-000) is Stryker's next-generation platform with CMOS sensors, DRE dark-cavity enhancement, and ENV near-infrared mode. The Stryker 1288 HD (1288-010-000) uses CCD sensors and was the predecessor platform. Both support nine specialty settings and 1920x1080p HD. Many hospital systems run both platforms across multi-specialty OR suites.
Specifications
Specifications
Resources
Resources
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.