Eizo's
RadiForce G33 and RadiForce G33-N are 3MP monochrome
LCD monitors for accurate diagnosis in medical
imaging applications, including PACS, CR, CT,
MRI and angiography. They have a 13-bit look-up
table that produces a palette of 8,161 grayscale
tones from which 4,096 (12-bit) tones can be
displayed simultaneously.
A 13-bit look-up table produces a palette of 8,161 grayscale tones from which 4,096 (12-bit) tones can be displayed simultaneously, ensuring a highly-refined grayscale. Along with aperture modulation technology, a different area ratio for each sub-pixel is displayed; providing a higher number of grayscale tones.
Selectable with the front panel buttons, the CAL Switch function allows for various calibration modes of different modalities such as CR, CT, and endoscope images. Furthermore, with ScreenManager Pro for Medical installed, auto mode settings can be made with the Auto CAL Switch function.
|
|
 |
|
Eizo RadiForce
G33 LCD Medical Display Monitor.
|
- 3
MP 20.8" Monochrome LCD Monitor
- 13-bit
look-up table that produces a palette of 8,161 grayscale
tones from which 4,096 (12-bit) tones can be displayed
simultaneously
- CAL
Switch function allows for various calibration modes
- Digital
Uniformity Equalizer (DUE) provides optimum uniformity
of the backlight's luminance
- Backlight
Saver helps reduce power consumption
- Built-in
Swing Sensor (also available without built-in censor
G33N-BK)
 |
Eizo's
RadiForce G33 and RadiForce G33-N are 3MP monochrome
LCD monitors for accurate diagnosis in medical
imaging applications, including PACS, CR, CT,
MRI and angiography. They have a 13-bit look-up
table that produces a palette of 8,161 grayscale
tones from which 4,096 (12-bit) tones can be
displayed simultaneously.
A 13-bit look-up table produces a palette of 8,161 grayscale tones from which 4,096 (12-bit) tones can be displayed simultaneously, ensuring a highly-refined grayscale. Along with aperture modulation technology, a different area ratio for each sub-pixel is displayed; providing a higher number of grayscale tones.
Selectable with the front panel buttons, the CAL Switch function allows for various calibration modes of different modalities such as CR, CT, and endoscope images. Furthermore, with ScreenManager Pro for Medical installed, auto mode settings can be made with the Auto CAL Switch function.